REFERENCE M40-P-H-R1-R1-S4

Description

Digital panel meter for process signals, for all type of industrial applications. Versatile and reliable, offers a wide range of references with a variety of output and control options and accesories. Its modular architecture provides flexibility to replace, add or change any of its internal modules to expand functionality as needed.

Accepts 4/20mA, 0/10Vdc, ±20mA and ±10Vdc signals, with 4 digit reading, scalable to any value between 9999 and -9999, and configurable decimal point. Provides excitation voltage from +5Vdc to +20Vdc to power up transducers.

Includes functions for segment linearization, fast acces to alarm setpoints, measure function and configurable alarm delays, among other functions.

Power : 85-265 Vac/Vdc isolated.

Options included :
2x Module R1 with 1 relay output for instruments from Series M, K, S and B. Relay with 3 contacts (NO, NC, Common) with swtiching up to 250Vac (max. 8A in series M, K, S and max. 3A in series B)
1x Module S4 with 1 RS-485 ASCII retrnamission output. Up to 57.6 kbps. Isolated. For instruments from Series M, K, S and B.

Characteristics

Type
  • Digital panel meter
Function
  • Process measure
Digits
  • 4
Signals accepted
  • mA
  • Vdc
Input Ranges
  • 4/20mA
  • 0/10Vdc
  • ±20mA
  • ±10Vdc
Excitation voltage
  • 5 to 20Vdc (max. 30mA)
Max. reading
  • 9999
Min. reading
  • -9999
Decimal point
  • configurable
Digit type
  • 7 segments led
Digit height
  • 14mm
Led color
  • Red
Power
  • 85/265 Vac/dc (isolated)
Consumption
  • <1.5W
Isolation
  • 2500 Veff
IP protection
  • IP65 front
Mounting
  • Panel mount
Connections
  • plug-in screw terminals
Front size
  • 96x48mm
Included functions
  • Fast access configurable menu
  • On power-up
  • Measure
  • Hysteresis
  • Alarms with configrable delays
  • Display filters
  • Memory of maximum reading
  • Memory of minimum reading
  • 5 configurable brightness levels
  • Password
Additional functions
  • Segment linearization

Series

No series


Models

There are no available models

Output and control Options

2xR1

Relay output
R1

S4

RS-485 ASCII retransmission
S4

Special Options

Other Options

Accessories

KA96

Format adapter to 96x96
KA96

THM

Benchtop housing
THM

DRA

DIN rail adapter
DRA

KIP

IP65 front protector
KIP

WME

Wall mounting housing.
WME

References

There are no available references