MODEL I4L

Description

Isolated signal converter for load cells and millivolt signals. Output signal in 4/20mA and 0/10Vdc. Isolated 3 ways.

Configurable to measure load cell signals from 0/5mV up to 0/80mV, also with bipolar ranges from ±5mV up to ±80mV. Provides +5Vdc excitation voltage to power the load cell.

Output signal configurable for 4/20 mA (active and passive) and 0/10 Vdc. Universal power supply from 18 to 265 Vac/dc. 3 way isolation between input, output and power circuits.

Output signal configurable for 4/20 mA (active and passive) and 0/10 Vdc. Universal power supply from 18 to 265 Vac/dc. 3 way isolation between input, output and power circuits.

Customizables input and output signals ranges. Configuration through front push-button keypad and front display. Configurable information messages (tare vale, mV at terminals, input signal value, output signal value, configured label, signal percentage, process value, excitation voltage value and excitation current value). Manual "force" functions to generate low and high output signals, to validate remote instrumentation during installation. "Tare" function. "Password" function to block non-authorized access to configuration menu. "SOS" mode to help on critical maintenance and repairs without affecting the manufacturing process.
Designed for industrial use, with potential integration into a wide range of applications. Optional customization.

Characteristics

Type
  • Signal converter and isolator
Function
  • DC votmeter
  • Load cells
Signals accepted
  • mVdc
Input Ranges
  • 0/5mV
  • 0/10mV
  • 0/15mV
  • 0/20mV
  • 0/25mV
  • 0/30mV
  • 0/40mV
  • 0/50mV
  • 0/60mV
  • 0/70mV
  • 0/80mV
  • ±5mV
  • ±10mV
  • ±20mV
  • ±30mV
  • ±40mV
  • ±50mV
  • ±60mV
  • ±70mV
  • ±80mV
Output signal
  • 4/20mA
  • 0/10Vdc
Power
  • 18/265 Vac/dc (isolated)
Isolation
  • 3000 Veff (input - output - power)
IP protection
  • IP30
Mounting
  • DIN rail mount
Width
  • 22.5mm
Included functions
  • Password
  • Tare function
  • "Force" functions
  • "SOS" function
  • "Messages" function

Series

No series


Models

There are no available models

Output and control Options

Special Options

Other Options

Accessories

There are no available accessories

References

I4L

Isolated signal converter for load cells and millivolt signals, with 18..265Vac/dc power supply Power 18-265 Vac/dc isolated.