Tel:. (+34) 93 729 6004     e-mail: web@fema.es

MODEL M60-C1

Series M

MODEL M60-C1

Digital panel meter - Series M

Datasheet - M60-C1User's Manual - M60-C1Quick Installacion Guide - M60-C1
Please enter your email before downloading the document

CONTACT NOW!

Description

Digital impulse counter, ratemeter and perdiometer for panel mount, for all type of impulse signals, and for all type of industrial applications. Versatile and reliable, offers a wide range of references with a variety of output and control options and accesories. Its modular architecture provides flexibility to replace, add or change any of its internal modules to expand functionality as needed.

Accepts impulse signals from a wide range of sensors (NPN, PNP, Namur, push-pull, pick-up, inductive, free-potential, quadrature, ...), with 6 digit reading, scalable to any value between 999999 and -199999, and configurable decimal point. Provides excitation voltage from +5Vdc to +18Vdc to power up transducers.

Includes functions for fast sensor configuration, multiple type of counting (add, substract, inhibit, quadrature, ...), fast acces to alarm setpoints, "trigger sense" function and configurable alarm delays, among other functions.


Main characteristics

    Type
  • Digital panel meter
    Function
  • Impulse counter
  • Ratemeter
  • Periodmeter
    Digits
  • 6
    Signals accepted
  • Push-pull
  • NPN
  • PNP
  • Namur
  • pick-up
  • TTL
  • inductivos
  • mechanical contact
  • quadrature signals from encoders
    Input Ranges
  • counter up to 250 KHz
  • ratemeter up to 500 KHz
  • periodmeter up to 500 KHz
    Excitation voltage
  • 5 to 18Vdc (máx 70mA)
    Digit type
  • 7 segments led
    Digit height
  • 14mm
    Led color
  • Red
  • Green
    Power
  • 85/265 Vac/dc (isolated)
  • 11/60 Vac/dc + 24-48Vac (isolated)
    Isolation
  • 2500 Veff
  • 1500 Veff
    IP protection
  • IP65 front
    Mounting
  • Panel mount
    Front size
  • 96x48mm front size
    Included functions
  • Fast access configurable menu
  • On power-up
  • On alarm
  • Hysteresis
  • Alarms with configrable delays
  • Display filters
  • Memory of maximum reading
  • Memory of minimum reading
  • 5 configurable brightness levels
  • Password
    Additional functions
  • Multiplier and divider scaling factors
  • Front reset
  • Rear reset
  • Configurable Preset


Series

There are no such models


Models

There are no such models


Out and control Options

R1

R1

Relay output
T1

T1

Isolated transistor output
AO

AO

Analog output
RTU

RTU

Modbus RTU retransmission
S2

S2

RS-232 ASCII retransmission
S4

S4

RS-485 ASCII retransmission


Special Options

R4

R4

Module with 4 relay output


Other Options

NBT

NBT

Without front keypad
G

G

Green digits


Accesories

KA96

KA96

Format adapter to 96x96
THM

THM

Benchtop housing
DRA

DRA

DIN rail adapter
KIP

KIP

IP65 front protector
WME

WME

Wall mounting housing.


References

M60-C1-H-R1-RTU

Impulse counter, ratemeter and periodmeter. 6 digits. Front size 96x48mm. Power 85-265 Vac/Vdc isolated. 1x Relay output + 1x Modbus RTU retransmission.

M60-C1-L-RTU

Impulse counter, ratemeter and periodmeter. 6 digits. Front size 96x48mm. Power 11-60 Vdc (24/48 Vac) isolated. 1x Modbus RTU retransmission.

M60-C1-L-NBT-G

Impulse counter, ratemeter and periodmeter. 6 digits. Front size 96x48mm. Power 11-60 Vdc (24/48 Vac) isolated. 1x Without front keypad + 1x Green digits.

M60-C1-L-T1-T1

Impulse counter, ratemeter and periodmeter. 6 digits. Front size 96x48mm. Power 11-60 Vdc (24/48 Vac) isolated. 2x Isolated transistor output.

M60-C1-H-AO-AO-RTU

Impulse counter, ratemeter and periodmeter. 6 digits. Front size 96x48mm. Power 85-265 Vac/Vdc isolated. 2x Analog output + 1x Modbus RTU retransmission.

M60-C1-L-AO-AO-RTU

Impulse counter, ratemeter and periodmeter. 6 digits. Front size 96x48mm. Power 11-60 Vdc (24/48 Vac) isolated. 2x Analog output + 1x Modbus RTU retransmission.

M60-C1-L-R1-RTU

Impulse counter, ratemeter and periodmeter. 6 digits. Front size 96x48mm. Power 11-60 Vdc (24/48 Vac) isolated. 1x Relay output + 1x Modbus RTU retransmission.

M60-C1-H

Impulse counter, ratemeter and periodmeter. 6 digits. Front size 96x48mm. Power 85-265 Vac/Vdc isolated.

M60-C1-H-NBT

Impulse counter, ratemeter and periodmeter. 6 digits. Front size 96x48mm. Power 85-265 Vac/Vdc isolated. 1x Without front keypad.

M60-C1-H-G

Impulse counter, ratemeter and periodmeter. 6 digits. Front size 96x48mm. Power 85-265 Vac/Vdc isolated. 1x Green digits.

M60-C1-H-R1

Impulse counter, ratemeter and periodmeter. 6 digits. Front size 96x48mm. Power 85-265 Vac/Vdc isolated. 1x Relay output.

M60-C1-H-R1-R1

Impulse counter, ratemeter and periodmeter. 6 digits. Front size 96x48mm. Power 85-265 Vac/Vdc isolated. 2x Relay output.

M60-C1-H-R1-R1-R1

Impulse counter, ratemeter and periodmeter. 6 digits. Front size 96x48mm. Power 85-265 Vac/Vdc isolated. 3x Relay output.

M60-C1-H-R1-R1-AO

Impulse counter, ratemeter and periodmeter. 6 digits. Front size 96x48mm. Power 85-265 Vac/Vdc isolated. 2x Relay output + 1x Analog output.

M60-C1-H-R1-R1-RTU

Impulse counter, ratemeter and periodmeter. 6 digits. Front size 96x48mm. Power 85-265 Vac/Vdc isolated. 2x Relay output + 1x Modbus RTU retransmission.

M60-C1-H-R1-R1-S4

Impulse counter, ratemeter and periodmeter. 6 digits. Front size 96x48mm. Power 85-265 Vac/Vdc isolated. 2x Relay output + 1x RS-485 ASCII retransmission.

M60-C1-H-R1-R1-S2

Impulse counter, ratemeter and periodmeter. 6 digits. Front size 96x48mm. Power 85-265 Vac/Vdc isolated. 2x Relay output + 1x RS-232 ASCII retransmission.

M60-C1-H-R1-AO

Impulse counter, ratemeter and periodmeter. 6 digits. Front size 96x48mm. Power 85-265 Vac/Vdc isolated. 1x Relay output + 1x Analog output.

M60-C1-H-R1-S4

Impulse counter, ratemeter and periodmeter. 6 digits. Front size 96x48mm. Power 85-265 Vac/Vdc isolated. 1x Relay output + 1x RS-485 ASCII retransmission.

M60-C1-H-R1-S2

Impulse counter, ratemeter and periodmeter. 6 digits. Front size 96x48mm. Power 85-265 Vac/Vdc isolated. 1x Relay output + 1x RS-232 ASCII retransmission.

M60-C1-H-AO

Impulse counter, ratemeter and periodmeter. 6 digits. Front size 96x48mm. Power 85-265 Vac/Vdc isolated. 1x Analog output.

M60-C1-H-AO-G

Impulse counter, ratemeter and periodmeter. 6 digits. Front size 96x48mm. Power 85-265 Vac/Vdc isolated. 1x Analog output + 1x Green digits.

M60-C1-H-AO-RTU

Impulse counter, ratemeter and periodmeter. 6 digits. Front size 96x48mm. Power 85-265 Vac/Vdc isolated. 1x Analog output + 1x Modbus RTU retransmission.

M60-C1-H-AO-S2

Impulse counter, ratemeter and periodmeter. 6 digits. Front size 96x48mm. Power 85-265 Vac/Vdc isolated. 1x Analog output + 1x RS-232 ASCII retransmission.

M60-C1-H-R4

Impulse counter, ratemeter and periodmeter. 6 digits. Front size 96x48mm. Power 85-265 Vac/Vdc isolated. 1x Module with 4 relay output.

M60-C1-H-R4-G

Impulse counter, ratemeter and periodmeter. 6 digits. Front size 96x48mm. Power 85-265 Vac/Vdc isolated. 1x Module with 4 relay output + 1x Green digits.

M60-C1-H-RTU

Impulse counter, ratemeter and periodmeter. 6 digits. Front size 96x48mm. Power 85-265 Vac/Vdc isolated. 1x Modbus RTU retransmission.

M60-C1-H-T1

Impulse counter, ratemeter and periodmeter. 6 digits. Front size 96x48mm. Power 85-265 Vac/Vdc isolated. 1x Isolated transistor output.

M60-C1-H-T1-T1

Impulse counter, ratemeter and periodmeter. 6 digits. Front size 96x48mm. Power 85-265 Vac/Vdc isolated. 2x Isolated transistor output.

M60-C1-H-S4

Impulse counter, ratemeter and periodmeter. 6 digits. Front size 96x48mm. Power 85-265 Vac/Vdc isolated. 1x RS-485 ASCII retransmission.

M60-C1-H-S2

Impulse counter, ratemeter and periodmeter. 6 digits. Front size 96x48mm. Power 85-265 Vac/Vdc isolated. 1x RS-232 ASCII retransmission.

M60-C1-L

Impulse counter, ratemeter and periodmeter. 6 digits. Front size 96x48mm. Power 11-60 Vdc (24/48 Vac) isolated.

M60-C1-L-G

Impulse counter, ratemeter and periodmeter. 6 digits. Front size 96x48mm. Power 11-60 Vdc (24/48 Vac) isolated. 1x Green digits.

M60-C1-L-R1

Impulse counter, ratemeter and periodmeter. 6 digits. Front size 96x48mm. Power 11-60 Vdc (24/48 Vac) isolated. 1x Relay output.

M60-C1-L-R1-R1

Impulse counter, ratemeter and periodmeter. 6 digits. Front size 96x48mm. Power 11-60 Vdc (24/48 Vac) isolated. 2x Relay output.

M60-C1-L-R1-R1-R1

Impulse counter, ratemeter and periodmeter. 6 digits. Front size 96x48mm. Power 11-60 Vdc (24/48 Vac) isolated. 3x Relay output.

M60-C1-L-R1-R1-AO

Impulse counter, ratemeter and periodmeter. 6 digits. Front size 96x48mm. Power 11-60 Vdc (24/48 Vac) isolated. 2x Relay output + 1x Analog output.

M60-C1-L-R1-R1-RTU

Impulse counter, ratemeter and periodmeter. 6 digits. Front size 96x48mm. Power 11-60 Vdc (24/48 Vac) isolated. 2x Relay output + 1x Modbus RTU retransmission.

M60-C1-L-R1-R1-S2

Impulse counter, ratemeter and periodmeter. 6 digits. Front size 96x48mm. Power 11-60 Vdc (24/48 Vac) isolated. 2x Relay output + 1x RS-232 ASCII retransmission.

M60-C1-L-R1-AO

Impulse counter, ratemeter and periodmeter. 6 digits. Front size 96x48mm. Power 11-60 Vdc (24/48 Vac) isolated. 1x Relay output + 1x Analog output.

M60-C1-L-R1-AO-AO-G

Impulse counter, ratemeter and periodmeter. 6 digits. Front size 96x48mm. Power 11-60 Vdc (24/48 Vac) isolated. 1x Relay output + 2x Analog output + 1x Green digits.

M60-C1-L-AO

Impulse counter, ratemeter and periodmeter. 6 digits. Front size 96x48mm. Power 11-60 Vdc (24/48 Vac) isolated. 1x Analog output.

M60-C1-L-AO-AO

Impulse counter, ratemeter and periodmeter. 6 digits. Front size 96x48mm. Power 11-60 Vdc (24/48 Vac) isolated. 2x Analog output.

M60-C1-L-R4

Impulse counter, ratemeter and periodmeter. 6 digits. Front size 96x48mm. Power 11-60 Vdc (24/48 Vac) isolated. 1x Module with 4 relay output.

M60-C1-L-R4-AO

Impulse counter, ratemeter and periodmeter. 6 digits. Front size 96x48mm. Power 11-60 Vdc (24/48 Vac) isolated. 1x Analog output + 1x Module with 4 relay output.

M60-C1-L-T1

Impulse counter, ratemeter and periodmeter. 6 digits. Front size 96x48mm. Power 11-60 Vdc (24/48 Vac) isolated. 1x Isolated transistor output.

M60-C1-L-S4

Impulse counter, ratemeter and periodmeter. 6 digits. Front size 96x48mm. Power 11-60 Vdc (24/48 Vac) isolated. 1x RS-485 ASCII retransmission.

M60-C1-L-S2

Impulse counter, ratemeter and periodmeter. 6 digits. Front size 96x48mm. Power 11-60 Vdc (24/48 Vac) isolated. 1x RS-232 ASCII retransmission.